0 Items in Cart

Appliance Parts Blog

XPRESS TECH IN A TUBE 1.5 TO 5 T

XPS-5T-TNT

$83.42   In-Stock

   

 
SKU: VAPXPS-5T-TNT

XPRESS TECH IN A TUBE 1.5 TO 5 T
Vapco TECH IN A TUBE XPS-5T-TNT for 1.5 to 5 Ton systems– detects and seals leaks, and protects refrigerant systems from moisture and acid. It contains the brightest ultraviolet dye and the fastest acting refrigerant sealer on the market. Tech in a Tube scours the system for moisture and eliminates and prevents acid.

Features and Benefits of Tech in a Tube
Fastest Acting Leak Sealer on the Market
UV Dye to Locate Leaks
Eliminates and Prevents Acid
Removes Moisture

Directions:
NO SPECIAL TOOLS REQUIRED

TRADITIONAL METHOD:
1. Turn the a/c system on and verify the unit is running. Connect Xpress Inject to the low-side service port of the system. (This is generally the large line).
2. Connect the manifold refrigerant hose to the refrigerant supply tank. Verify the high and low side valves on the manifold are closed before proceeding. Purge the low-pressure hose when connecting to Xpress Inject.
3. Open the low-side valve and watch for the tube to clear. (This will ONLY take a few seconds!) Turn off the low-side manifold valve as soon as the tube is clear. Turn off refrigerant gas. Verify the system is charged to the manufacturer’s specifications! Disconnect low-side hose from Xpress Inject. Install service port cap. Run the a/c unit at least one hour after installing Xpress Inject. (Do not bend or kink hose!)

DIRECTIONS FOR DIRECT INJECT HOSE:
Turn the A/C system on and then check to see if the compressor is on and the system is fully charged.

Ensure the ball valve is closed before attaching the “A” side of the hose to the high-pressure service port.

Barely thread the male end of the injector tube to the “B” side of the hose. Do not depress the valve. Next, crack open and close the ball valve to remove air from the hose. Then, thread the tube into the “B” side of the hose.

Connect the female end of the injector tube to the low-pressure service port and then open the ball valve. Let refrigerant flow through and then inject the product into the system. Close the ball valve and then disconnect the hose and injector from the unit.

Remove the tube from the “B” side of the hose and open the ball valve to release charge. This prevents contamination.

INSTALLATION WITH VAPCO DIRECT INJECT GUN:
Turn the A/C system on and verify the unit is running. With the CO2 cartridge in the gun, connect the Xpress Inject to the Direct Inject Gun. Connect the other end to the low-side service port. Briefly pull the trigger. The direct Inject Gun will meter just enough CO2 to the empty tube. The sealer has now been injected into the system. Disconnect the empty tube from the low-side port. Install service port cap. Run the A/C unit at least one hour after installing Xpress Inject. 12+ uses per CO2 cartridge.

Vapco Products Logo  

Similar Products Found in:
>   Leak Seal Products

Have a question about this part?
Ask us a question about part number XPS-5T-TNT

Store Availability

 Huntsville, AL In-Stock
 Albertville, AL N/A
 Decatur, AL N/A
 Dothan, AL N/A
 Gadsden, AL In-Stock
 Huntsville, AL NW In-Stock
 Jasper, AL N/A
 Mobile, AL N/A
 Montgomery, AL N/A
 Pensacola, FL N/A
 Salisbury, MD N/A

Prices for online orders only. Price and availability subject to change - customer will be notified if any changes are necessary.

A-1 Appliance Supports Wellhouse in their fight against human trafficking.